Main Features

  • Device Function: Open Circuit Testing, Short Circuit Testing, Split Pair Testing
  • Network (RJ-45): Yes
  • Number of Network (RJ-45) Ports: 2
  • Battery Size Supported: AA
  • Height: 3.3
  • Width: 2
  • Depth: 1.3
  • Weight (Approximate): 2 lb
Brand
Brand Name
Ideal Industries

Physical Characteristics
Dimensions
3.3 Height x 2 Width x 1.3 Depth
Height
1.7
Length
4.7
Weight (Approximate)
2 lb
Width
9.8

Controls/Indicators
Status Indicators
    • Battery low LED
    • OPEN - There is no OPEN LED indication. A typical cable may have 2, 3, or 4 pairs. OPENS are displayed as an unlit LED. The user will determine if a pair is present and continuous or OPEN by comparing the illuminated LEDs to the expected number of pairs that should be good. For example, when testing a 4 pair cable, three illuminated LEDs in the PASS area indicate the presence of an OPEN condition in one of the pairs
    • SHORT - A short circuit condition exists
    • MISWIRE - Indicates the improper assignment of individual wire pairs to pins for the wiring schemes tested. Tester checks T568A, T568B, 10Base-T, and Token Ring configurations
    • REVERSAL - Reverse wiring means the pin for one wire in a pair is connected to the opposite pin for the pair in the remote jack
    • SPLITPAIRS - Split Pairs occur when the tip (positive conductor) and ring (negative conductor) of two twisted pairs are interchanged
    Pass Indicators:
    • T568A and T568B
    • Four green LEDs on pairs 1-2, 3-6, 4-5, and 7-8. All four pairs are terminated correctly
    • Token Ring
    • Two green LEDs on pairs 3-6, and 4-5. Both pairs terminated correctly
    • 10 Base-T
    • Two green LEDs on pairs 1-2, and 3-6. Both pairs terminated correctly
    • Shield
    • Green SHIELD LED indicates the shield on the cable is correctly and continuously wired through the modular plug termination
    FAIL Indicators:
    • A flashing pair LED indicates that this wire pair has a fault. A flashing LED in the FAIL section will indicate which fault was detected. Multiple flashing LEDs indicate multiple pairs and/or multiple faults. Best practice is to correct cable faults until cable is verified as correct with appropriate green LEDs

Interfaces/Ports
Ports
  • 1 x RJ-45 Network
  • 1 x RJ-45 Network Remote

Battery Information
Batteries
AA

General Information
Manufacturer
IDEAL Industries, Inc
Manufacturer Part Number
62-200
Product Line
LinkMaster PRO
Product Type
Network Testing Device

Technical Information
Length Measurement
36 to 600 ft STP/UTP
Test Services
  • Open circuits
  • Shorts
  • Miswires
  • Reversals
  • Split pairs
  • SHIELD detection tests a cable's shield integrity
  • Checks continuity and configuration of wiring with unshielded and shielded modular plugs
  • Remote has wiring chart identifying T568A and T568B wiring configurations
  • DEBUG quickly identifies which cable pairs have a specific wiring fault