LINK MASTER
Product #: ADV-IL-62200
Availability:
SPECIAL ORDER
*Not available for expedited delivery
Main Features
- Device Function: Open Circuit Testing, Short Circuit Testing, Split Pair Testing
- Network (RJ-45): Yes
- Number of Network (RJ-45) Ports: 2
- Battery Size Supported: AA
- Height: 3.3
- Width: 2
- Depth: 1.3
- Weight (Approximate): 2 lb
Brand
Brand Name
Ideal Industries
Physical Characteristics
Dimensions
3.3 Height x 2 Width x 1.3 Depth
Height
1.7
Length
4.7
Weight (Approximate)
2 lb
Width
9.8
Controls/Indicators
Status Indicators
- Battery low LED
- OPEN - There is no OPEN LED indication. A typical cable may have 2, 3, or 4 pairs. OPENS are displayed as an unlit LED. The user will determine if a pair is present and continuous or OPEN by comparing the illuminated LEDs to the expected number of pairs that should be good. For example, when testing a 4 pair cable, three illuminated LEDs in the PASS area indicate the presence of an OPEN condition in one of the pairs
- SHORT - A short circuit condition exists
- MISWIRE - Indicates the improper assignment of individual wire pairs to pins for the wiring schemes tested. Tester checks T568A, T568B, 10Base-T, and Token Ring configurations
- REVERSAL - Reverse wiring means the pin for one wire in a pair is connected to the opposite pin for the pair in the remote jack
- SPLITPAIRS - Split Pairs occur when the tip (positive conductor) and ring (negative conductor) of two twisted pairs are interchanged
- T568A and T568B
- Four green LEDs on pairs 1-2, 3-6, 4-5, and 7-8. All four pairs are terminated correctly
- Token Ring
- Two green LEDs on pairs 3-6, and 4-5. Both pairs terminated correctly
- 10 Base-T
- Two green LEDs on pairs 1-2, and 3-6. Both pairs terminated correctly
- Shield
- Green SHIELD LED indicates the shield on the cable is correctly and continuously wired through the modular plug termination
- A flashing pair LED indicates that this wire pair has a fault. A flashing LED in the FAIL section will indicate which fault was detected. Multiple flashing LEDs indicate multiple pairs and/or multiple faults. Best practice is to correct cable faults until cable is verified as correct with appropriate green LEDs
Interfaces/Ports
Ports
- 1 x RJ-45 Network
- 1 x RJ-45 Network Remote
Battery Information
Batteries
AA
General Information
Manufacturer
IDEAL Industries, Inc
Manufacturer Part Number
62-200
Product Line
LinkMaster PRO
Product Type
Network Testing Device
Technical Information
Length Measurement
36 to 600 ft STP/UTP
Test Services
- Open circuits
- Shorts
- Miswires
- Reversals
- Split pairs
- SHIELD detection tests a cable's shield integrity
- Checks continuity and configuration of wiring with unshielded and shielded modular plugs
- Remote has wiring chart identifying T568A and T568B wiring configurations
- DEBUG quickly identifies which cable pairs have a specific wiring fault